Glossary on
|
Contact EVISA
|
Sitemap
|
Home
Training
QA/QC
Analytical Services
Database
Consultancy
Research
Newsletter
Vacancies
Training
Training
QA/QC
QA/QC
Analytical Services
Analytical Services
Database
Database
Consultancy
Consultancy
Research
Research
Newsletter
Newsletter
Vacancies
Vacancies
EVISA - Who we are
About Speciation
Discussion Forum
Services
Links
Glossary
EVISA - Who we are
EVISA - Who we are
About Speciation
About Speciation
Discussion Forum
Discussion Forum
Services
Services
Links
Links
Glossary
Glossary
Search
The establishment of EVISA is funded by the EU through the Fifth Framework Programme (G7RT- CT- 2002- 05112).
Supporters of EVISA includes:
Material Database:
BCR-701 - Lake sediment
Type
Certified reference material
Producer
JRC - Joint Research Centre
Status
Available
Material
Powder
Reference
BCR-701
Catalog (Web)
https://irmm.jrc.ec.europa.eu/html/reference_materials_cat
alogue/catalogue/attachements/BCR-701_report.pdf
Description
Extractable trace elements in sediment following a sequential extraction procedure
keywords:
Environmental material
,
Soil/Sediment
,
Trace elements
,
Heavy metals
,
Fractionation analysis
Package
Sediment sample in a glass bottle containing about 20 g of powder
Parameter
Analyte
Cadmium
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
0.13 +/- 0.08 mg / kg; 11.7 +/- 1.0 mg / kg
Analyte
Cadmium
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
7.34 +/- 0.35 mg / kg; 3.77 +/- 0.28 mg / kg; 0.27 +/- 0.06 mg / kg
Analyte
Chromium
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
2.26 +/- 0.16 mg / kg; 45.7 +/- 2.0 mg / kg; 143 +/- 7 mg / kg
Analyte
Chromium
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
62.5 +/- 7.4 mg / kg; 272 +/- 20 mg / kg
Analyte
Copper
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
49.3 +/- 1.7 mg / kg; 124 +/- 3 mg / kg; 55.2 +/- 4.0 mg / kg
Analyte
Copper
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
38.5 +/- 11.2 mg / kg; 275 +/- 13 mg / kg
Analyte
Lead
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
3.18 +/- 0.21 mg / kg; 126 +/- 3 mg / kg; 9.3 +/- 2.0 mg / kg
Analyte
Lead
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
11.0 +/- 5.2 mg / kg; 143 +/- 6 mg / kg
Analyte
Nickel
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
41.4 +/- 4.0 mg / kg; 103 +/- 4 mg / kg
Analyte
Nickel
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
15.4 +/- 0.9 mg / kg; 26.6 +/- 1.3 mg / kg; 15.3 +/- 0.9 mg / kg
Analyte
Zinc
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
95 +/- 13 mg / kg; 454 +/- 19 mg / kg
Analyte
Zinc
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
205 +/- 6 mg / kg; 114 +/- 5 mg / kg; 45.7 +/- 4.0 mg / kg
Events
See the complete list of deadlines!
EGU General Assembly 2025
27.04.2025
Vienna, Austria
SETAC Europe 35th Annual Meeting
11.05.2025
Vienna, Austria
Spectr’Atom 2025
26.05.2025
Holiday Inn Kingston Waterfront, Kingston, ON, K7L 1A2, Canada
... more Events
News
What's new on EVISA's web site ?
Selenium, Mercury, and Health Benefit Values of Ocean Fish of the Central North Pacific
Standard Methods for the Determination of Per- and Polyfluoroalkyl Substances (PFAS)
Typical Challenges for PFAS Analysis
Techniques for the determination of PFAS (per- and polyfluoroalkyl substances)
... more News
Join usergroup
User:
Password:
You have forgotten your password ?
Imprint
Disclaimer
© 2003 - 2025 by European Virtual Institute for Speciation Analysis ( EVISA )