Agilent Technologies Inc. - G1329A (1200 Series) Standard Autosampler
|
|
|
|
|
|
|
Year of introduction |
2006 |
Status |
available |
Company |
Agilent Technologies Inc.
|
Categories |
Automation: Autosampler (LC) |
Reliability and Ease of Use
The Agilent 1200 Series standard autosampler is designed for the reliability, safety, and ease of use needed in pharmaceutical routine tasks and quality control, as well as for environmental and food analyses. It can be upgraded from non-thermostatted version to thermostatted version by adding the Agilent 1200 Series thermostat for ALS/FC/spotter.
Features
- Reliable injections from 0.1 µL to 100 µL.
- Easy adaption for injection volumes up to 1500 µL for applications ranging from microbore to semipreparative chromatography.
- Low internal volume of 300 µL for the minimum contribution to a system's total internal volume can be even further reduced using "by-pass" mode.
- Overlapped injections for increased productivity.
- Peltier temperature control from 4 to 40 °C for up to 100 2-mL vials containing thermally-labile samples (upgrade from non-thermostatted to thermostatted version possible.
|
Specifications |
|
Performance Specifications 1200 Series standard autosampler Valid when standard 100 µL metering head installed | Injection range | 0.1- 100 µL in 0.1 µL increments Up to 1500 µL with multiple draw (hardware modification required) | Precision | <0.25% RSD from 5-100 µL, <1% from 1-5 µL, variable volume | Sample viscosity range | 0.2 - 5 cp | Sample capacity | 100 × 2-ml vials in 1 tray 40 × 2-ml vials in ˝ tray 15 × 6-ml vials in ˝ tray (Agilent vials only) | Injection cycle time | Typically 50 s depending on draw speed and injection volume | Carry-over | Typically < 0.1 %, < 0.05 % with external needle cleaning | Performance Specifications 1200 Series standard autosampler Valid when standard 900 µL metering head installed | Injection range | 0.1 - 900 µL in 0.1 µL increments (recommended 1 µL increments) Up to 1800 µL with multiple draw (hardware modification required) | Precision | Typically < 0.5 % RSD of peak areas from 5 - 2000 µL Typically < 1 % RSD of peak areas from 2000 - 5000 µL Typically < 3 % RSD of peak areas from 1 - 5 µL Variable volume | Sample viscosity range | 0.2 - 5 cp | Sample capacity | 100 × 2-ml vials in 1 tray 40 × 2-ml vials in ˝ tray 15 × 6-ml vials in ˝ tray (Agilent vials only) | Injection cycle time | Typically 50 s depending on draw speed and injection volume | Carry-over | Typically < 0.1 %, < 0.05 % with external needle cleaning | Pressure operating range | 0-20 MPa (0-200 bar, 0-2950 psi) |
|
|