Agilent Technologies Inc. - G1354A (Series 1200) Quaternary Pump
|
|
|
|
|
|
|
Year of introduction |
2006 |
Status |
available |
Company |
Agilent Technologies Inc.
|
Categories |
Chromatography: LC-Pump Chromatography: LC-Pump: Gradient/Binary Chromatography: LC-Pump: Gradient/Quarternary Chromatography: LC-Pump: Gradient/Ternary |
Low pressure mixing of up to four solvents
The Agilent 1200 Series quaternary pump with incorporated vacuum degasser ensures virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. The variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvents and is maintenance free. The Agilent 1200 Series quaternary pump provides highest flexibility in solvent mixing and is recommended for a wide range of research and routine applications, and in the method development area.
Features:
- Application focus: Routine applications in the environmental and food area, as well as method development in the pharmaceutical industry
- Speeds up method development, preparation of mobile phases and flushing the HPLC system by offering convenient access of up to four solvents for isocratic or gradient analysis.
- Keeps maintenance to a minimum for lower operation costs by using robust materials such as stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE. Optional active seal wash option for high salt mobile phases to prevent corrosion.
- Wide flow range of up to 10 mL/min for broad HPLC work, including semipreparative separations.
- Easy programming and control through handheld controller, instant pilot, or through Agilent data systems, e.g. the Agilent ChemStation.
- More help for GLP using the built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.
|
Specifications |
|
| | Specifications Agilent 1200 Series Quaternary Pump | Flow | Flow precision | ≤0.07 % RSD,or ≤0.02 min SD whatever is greater, based on retention time at constant room temperature | Flow accuracy | ± 1 % or 10 µL/min whatever is greater | Range | Setpoints from 0.001 to 10.0 ml/min, in 0.001 ml/min increments | Pressure | Operating range | 0 - 40 MPa (0 - 400 bar, 0 - 5880 psi) up to 5 ml/min 0 - 20 MPa (0 - 200 bar, 0 - 2950 psi) up to 10 ml/min | Pulsation | <2 % amplitude (typically <1 %) at 1 mL/min isopropanol at all pressures >1 MPa (> 10 bar, >147 psi) | Compressibility compensation | User selectable, based on mobile phase compressibility | Gradient | Delay volume | 800 - 1100 µL depending on back pressure | Composition precision | <0.20 % SD, at 0.2 and 1 mL/min | Recommended pH range |
| 1.0 - 12.5 Solvents with pH <2.3 should not contain acids which attack steel |
|
|
|