Instrument Database:
Agilent Technologies Inc. - G1367C (1200 Series) High Performance Autosampler SL
|
|
|
|
|
|
|
Year of introduction |
2006 |
Status |
available |
Company |
Agilent Technologies Inc.
|
Categories |
Automation: Autosampler (LC) |
For Rapid Resolution LC
The Agilent 1200 Series high performance autosampler SL is specifically designed for the Agilent 1200 Series Rapid Resolution system for increased analysis speed with uncompromised sensitivity, resolution, and precision. It can be upgraded from non-thermostatted to thermostatted version by adding the Agilent 1200 Series thermostat for ALS/FC/spotter.
Features
- Increased pressure range enabling the use of today\'s column technology (sub-two-micron columns) with the Agilent 1200 Rapid Resolution system.
- High speed with lowest carry-over by flow through design.
- Increased sample injection speed for high sample throughput.
- Increased productivity by using overlapped injection mode.
- Minimal delay volumes for rapid gradients and fast equilibration when bypassing the autosampler after sample injection.
- Flexible and convenient sample handling with different types of sample containers, such as vials and well plates. Using 384-well plates allows you to process up to 768 samples unattended.
- Peltier temperature control from 4 to 40° C for thermally-labile samples (upgrade from non-thermostted to thermostatted version possible).
|
Specifications |
|
Performance specifications Agilent 1200 Series high performance autosampler SL | Communications | Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output | Safety features | Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display | Injection range | 0.1- 100 µL in 0.1 µL increments Up to 1500 µL with multiple draw (hardware modification required) | Precision | <0.35 % RSD from 5-100 µL <1 % from 1-5 µL variable volume | Sample viscosity range | 0.2 - 5 cp | Sample capacity | 2 × well-plates (MTP) + 10 × 2 ml vials 108 × 2-mL vials in2 × 54 vial plate plus 10 additional 2-mL vials 30 × 6-mL vials in 2 x 15 vial plate plus 10 additional 2-mL vials 54 Eppendorf tubes (0.5/1.5/2.0mL) in 2 × 27 Eppendorf tube plate Also compatible with the Agilent 1200 Series sample capacity extension for further expansion of the sample capacity | Injection cycle time | Typically < 30 s using following standard conditions: Default draw speed: 200 µLl/min Default eject speed: 200 µL/min Injection volume: 5 µL | Carry-over | Typically < 0.01 % using the following conditions: Column: 125 x 4 mm Hypersil ODS, 5 µm Mobile phase: water/acetonitrile = 80/20 Flow rate: 1 mL/min Injection volume: 1 µL caffeine (1 mg/ml), 5 µL water to test carryover Outside wash of needle before injection: 20 sec with water using flush port | GLP features | Early maintenance feedback (EMF), electronic records of maintenance and errors |
|
|