Instrument Database:
Alcott Chromatography Inc. - 719AL Variable Volume Autosampler
|
|
|
|
|
|
|
Year of introduction |
|
Status |
available |
Company |
Alcott Chromatography Inc.
|
Categories |
Automation: Autosampler (LC) |
The Alcott Model 719AL autosampler is a syringe style, partial or full-loop injection autosampler that accepts 8mm, 12mm or 15mm vials or microplates. Three injection volume ranges are available by choosing a 50µL, 250µL or 2mL syringe. Designed for HPLC and LC/MS applications, the 719al provides superior precision, accuracy, flexibility and reliability to your system. OPERATION Emulating a manual HPLC injection process, the 719AL has zero sample loss and can reproducibly make 1µL injections from micro inserts containing as little as 3µL of total sample. The diagram below illustrates the mechanical steps for injections with the Model 719AL.
BENEFITS - Accurate injection volumes from 0.06µL to 2mL using partial or full loop
- Internal and external needle rinse to eliminate carryover
- Optional vial trays available in three vial sizes plus microplates
- Automated dilutions, mixing, derivatizations and sample preparations
- Selectable needle depth
- Windows or EZChrom Elite 2.5 software control
- Simple to use and maintain
- System interface through RS-232, IEEE, Contact Closures and I2C
- Customized software features available
|
Specifications |
|
Design Type: | Variable Volume, XYZ movement, syringe loading | Tray Capacities: | 50 (15mm), 72 (12mm), or 128 (8mm) sample vials. Also, four 12 mm vials for standards or rinses | Injections Per Vial: | Unlimited | Rinse Strokes | 0-99 for needle port and needle | Precision: | Less than or equal to ±0.5% RSD, for 10µL partial loop injections under ACI test conditions | Linearity: | r2 <= 0.99 | Carryover: | Less than 0.01% with rinse under ACI test conditions | Sample Waste: | None (or user selectable) | Keypad: | 20 key, 4 line, 80 character LCD | Injection Parameters: | Partial or fixed loop, sample draw speed, delay time, needle depth, pre-injection volume, pre/post-air volume, rinse strokes, rinse rate, pre pierce | Syringe: | 50, 250 (standard), or 2000 µL total volume | Valve: | Valco Cheminert C3 valve with 300µL loop and high speed actuator | Programming: | 10 Methods, maximum 128 steps per method. Priority sampling | Communications: | Interfaces: RS-232-C, IEEE, I2C Outputs:BCD, parallel printer port, inject market, 4 user selectable NO or NC Contact Closures with user selectable closure duration times. | Dimensions: | 33cm H x 32cm W x 55cm D (13" x 13" x 21") Weight: 14 Kg (31 lbs.) Weight: 17 Kg (38 lbs.) Refrigerated | Wetted Materials: | Teflon, 316 stainless steel and nitronic 60 | Voltage: | Autoselectable: 100-240 VAC ±10%, 47-63 Hz |
|
|