Instrument Database:
Applied Biosystems - Q TRAP® LC/MS/MS System
|
|
|
|
|
|
|
Year of introduction |
|
Status |
historical ( out of sale ) |
Company |
Applied Biosystems
|
Categories |
Hyphenated Techniques: LC-MS Mass spectrometer: ESI-MS Mass spectrometer: LC-MS |
- Identify and characterize more proteins and metabolites faster and easier using patented linear iontrap technology.
- Get exceptional sensitivity, higher resolution, and improved mass accuracy.
- Significantly enhance your efficiency, productivity, and confidence in results.
- Generate fast, full scans at high sensitivity and get a wide dynamic range required for accurate quantitation.
Unmatched Performance for Drug Discovery and Proteomics The Q TRAP® LC/MS/MS System is a hybrid triple quadrupole/linear ion trap mass spectrometer that outperforms any conventional ion trap and delivers all the functionality of a high-performance triple quadrupole. The compact, benchtop system is rugged enough for continuous high-throughput operation. Get high confidence results in less time and avoid losing structural information with information-rich MS/MS and MS3 spectra.
Advanced Scanning Capabilities Information Dependent Acquisition (IDA) lets you focus only on ions of interest. Get more information with fewer experiments using multiply charged, neutral loss, and precursor ion scans.
Integrate with Powerful, Industry-Leading Software Put the Q TRAP system's sophisticated performance features at your fingertips with Analyst®, BioAnalyst™, Metabolite ID, Pro ID and Pro ICAT software. Simplify how you develop methods, and acquire and process data. For Research Use Only. Not for use in diagnostic procedures.
|
Specifications |
|
Computer Requirements (PC) Operating System Windows NT CPU 1.7 GHz Memory 512 SDRAM CD-ROM 17/40X Floppy 1.44 MB Display 20" Viewable Color monitor recommended Hard Disk 40GB
Performance/Throughput Dynamic Range 1cps to 4x106 cps(pulse counting) Mass Range m/z 5-1,700 in quad mode, m/z 50-,1700 in Linear Ion Trap mode Scan speed up to 4000amu/sec in linear ion trap mode
Physical Specifications Width 105cm (41in) Height 62cm (25in) Weight 111kg (244lb) Depth 50cm (20in)
Power Requirements Circuit Current 15 A grounded single phase circuit Power Consumption 2500VA max Voltage 2 separate 207 V minimum to 242 V maximum Frequency Hz 50/60 Hz
System Setup Specifications Gas Supplies 60 psi UHP nitrogen, 100 psi zero air, 60 psi filtered, dry air IP address Ion Source High Voltage, Ion Source Exhaust, Low Vacuum
|
Related links:
|