Instrument Database:
Beijing Rayleigh Analytical Instrument Corporation (BRAIC) - WFX-320 Atomic Absorption Spectrophotometer
|
|
|
|
|
|
|
Year of introduction |
|
Status |
available |
Company |
Beijing Rayleigh Analytical Instrument Corporation (BRAIC)
|
Categories |
Spectrometer ( Atom. ): AAS: Flame |
Specifications |
|
Main Specification Wavelength range 190-900nm Wavelength accuracy ±0.5nm Resolution Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. Baseline stability 0.005A/30min Background correction The D2 lamp background correction capability at 1A is better than 30 times. Light Source System Lamp number 2 lamps (one preheating) Lamp current adjustment Micro-computer control Adjustment range: 0~20mA, Lamp power supply mode Powered by square pulses Optical System Monochomator Single beam, Czerny-Turner design grating monochromator Grating 1800 l/mm Focal length 277mm Blazed Wavelength 250nm Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.2nm Detection and Data Processing System Detector Photomultiplier with high sensitivity and wide spectral range. Electronic and micro-computer system Light energy and negative high-voltage auto-balance Display mode LED display of energy and measurement values, concentration direct reading Read mode transient, integral, peak height, peak area. Integral or sampling time is in the range of 0.1-19.9s. Scale expansion 0.1~99 Data processing mode Automatic calculation of mean, standard deviation and relative standard deviation. Repeating number is in the rang of 1-99 Measurement mode 3~7 standards can be determined for curve fitting. Sensitivity correction available. Result printing Measurement data, working curve, signal profile and analytical conditions can all be printed out. Instrument self-check Check current status of each function key Flame Analysis Burner 10cm single slot all-titanium burner Spray chamber All-plastic spray chamber. Nebulizer High efficiency glass nebulizer with metal sleeve. Position adjustment Adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner. Gas line protection Fuel gas leak alarm Characteristic Concentration and Detection Limit Air-C2H2 flame Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L; Function Expansion Flameless analysis with WF-1C graphite furnace system available. Hydride vapor generator can be connected for hydride analysis. Dimensions and Weight 1020 x 490 x 540 mm, 80kg unpacked
|
|