CSL Gas Chromatograph System sets the standard for reliable performance in wide range of applications. Both gas and liquid samples may be analyzed on this unit. Samples can be introduced via sampling valves or by syringe. A complete selection of valves for back flush, heart-cut via column switching, as well as series/by pass operations are available, up to three valves, manually or pneumatically actuated may be installed. Pneumatically actuated valves can be remotely operated. A heated valve housing is also available for high temperature gas/liquid analysis applications. System can be configured to various detectors such as TCD, FID, PID, ECD, FPD and HID. GC can be operated at temperatures from ambient to 450°. Temperature readout is displayed digitally with selector switches provided to set and read desired temperatures. System can be configured as per customer's requirement.
|
Specifications |
|
(dual detector – upgradeable upto 4 detectors) Gas chromatograph with complete automated system with complete control of all instrument functions from software. GC will have the facility of TCD protection circuit, oven heat protection, Electronic pressure controller, advance diagnostics of all instrument parameter, inbuilt integrators for data acquisition system, fast auto cooling oven, provision for FPD, PID, HID, ECD etc. Three-injection port facility-two for packed column one for capillary, gas chromatograph optional attachments includes headspace sampler, cryogen attachments and configuration in multidimention steps for any standards such as ASTM or EPA or IS. Mechanizer for ppm level analysis of CO & CO2, Can be configured to any ASTM methods. Applications: Natural Gas analyzers, Gas Monitoring System, Refinery gas analyzers, Dissolved gases in Transformer oil Environmental G.C. configurations sulphur gas G.C., Mud gas chromatograph, Hydrocarbon GC configurations, etc.
Description | Model No. | 7045 | Detector | Dual (up to Three) | Injection System (Controlled from PC with Software common for all models) | Dual or Triple Port with 2 packed column and 1 PTV with spli/splitless port. | Operating Temp. Range | Ambient to 450°C | Pressure Control System | Electronic pressure controller for Air & H2/ Digital flow controller for Carrier gas flows with complete control from software. | Column Oven Temp (Controlled from PC with Software common for all models) | Ambient to 450°C, reach within 10 min. max volume 9 Ltrs. Can hold 2 packed columns and 1 capillary. (60 meter) | Cooling Speed | 450°C to 50°C within 10 min. (Auto Control) | Over Heat Protection | Available Hardware / Software | Temp Programming | Ambient to 450°C (0.1°C/ min to 50°C/ min 20°C after 350°C with 7 ramps. | Optional Facility | Methanizer, (For detection of CO2 & CO in ppm level) cryogenic attachment for low temp (up to-99°C) application. Headspace sampler (HS) for batch analysis. Can be configured as per any standards such as ASTM or EPA methods with suitable dedicated software with analysis as per the method. | Accessories | Porapack-Pack column/DC 200 pack column, Gas tight syringe, septa, carrier gas cylinders, 24 bit data integrator & PC with printer | Weight | Approx 25 kg |
|
|