Instrument Database:
Chemtron Science Laboratory PVT LTD - CSL Gas Chromatograph Model No. 1045
|
|
|
|
|
|
|
Year of introduction |
|
Status |
available |
Company |
Chemtron Science Laboratory PVT LTD
|
Categories |
Chromatography: GC |
CSL Gas Chromatograph System sets the standard for reliable performance in wide range of applications. Both gas and liquid samples may be analyzed on this unit. Samples can be introduced via sampling valves or by syringe. A complete selection of valves for back flush, heart-cut via column switching, as well as series/by pass operations are available, up to three valves, manually or pneumatically actuated may be installed. Pneumatically actuated valves can be remotely operated. A heated valve housing is also available for high temperature gas/liquid analysis applications. System can be configured to various detectors such as TCD, FID, PID, ECD, FPD and HID. GC can be operated at temperatures from ambient to 450°. Temperature readout is displayed digitally with selector switches provided to set and read desired temperatures. System can be configured as per customer's requirement.
|
Specifications |
|
(single detector – PID, FPD, ECD, HID, TCD or FID) Gas Chromatograph will have the facility of pressure regulator valve / pneumatics mass flow controller integrators, manual cooling oven. Operating sensitivity mode (low/ medium/ high). The data system will have facility of control of instrument conditions, display of chromatograms, quantification of analysis and storage of analytical data. CSL-1045 gas chromatograph also having optional facility of methanizer, manual sampling valve, split/spitless injection port for FID for dedicated analysis. Applications: University/ College/ Educational, etc. Description | Model No. | 1045 | Detector | Single | Injection System (Controlled from PC with Software common for all models) | Single Port (Dual optional application specific). | Operating Temp. Range | Ambient to 350°C | Pressure Control System | Pressure regulator for Carrier as well as Air & H2 for FID Mass flow controller for Carrier gas. (Optional) TCD. | Column Oven Temp (Controlled from PC with Software common for all models) | Ambient to 350°C, reach within 6 min max. volume 4 Ltrs. enough for 2 packed column. | Cooling Speed | 350°C to 50°C within 10 min. (Manual Control) | Over Heat Protection | Available Hardware / Software | Temp Programming | Ambient to 350°C (0.1°C/ min to 50°C/ min) with 7 ramps. | Optional Facility | Methanizer, (For Detection of CO2 & CO in ppm level) 24 bit of software with PC having facility of control instrument condition, display of chromatogram, quantification of analysis and storage of analytical data. | Accessories | Packed column silica gel/ molecular sive 13 x Gas tight syringe, septa, Carrier gas Cylinders, 24 Bit data integrator & PC with printer. | Weight | Approx 8 kg |
|
|