Instrument Database:
HTA s.r.l. - HT280T GC-Autosampler
|
|
|
|
|
|
|
Year of introduction |
2007 |
Status |
available |
Company |
HTA s.r.l.
|
Categories |
Automation: Autosampler (GC/Head Space) Automation: Autosampler (GC/Liquid) Automation: Workstation Separation: Extraction: SPME |
The HT280T is an all-in-one sampler that combines in a single unit a traditional liquid sample injection, a static headspace and a SPME (Solid Phase micro-extraction) sampler.
Changing from Liquid to Headspace or to SPME is as simple as changing the sample tray, syringe and vial sensor — about 5 minutes in total without the need to remove the sampler from the GC.
The HT280T simply maximizes the efficiency of a single GC system. It is available for little more than the cost of the headspace autosampler alone!
|
Specifications |
|
Headspace Operation Shaking method: | Orbital | Incubation oven:
| 6 position | Syringe Size: | 2.5ml | Tray Capacity: | 40 Vials, 10 or 20ml | Cleaning System: | Nitrogen flush
| Conditioning | | Oven Temperature: | 40 - 150°C | Time: | 0 - 23h 59m
| Progressive Increase: | 0 - 9h 59m | Shaker Speed: | 320 - 720 rpm | Shaking Cycles On/Off: | 0 - 9.9 mins | Sampling | | Syringe Temperature: | 40 - 150°C | Pre-fill Volume: | Steps of 0.01ml | Pull Up Strokes: | Up to 15 Strokes | Equilibrium Delay: | Up to 60 secs | Sampling Volume: | Steps of 0.01ml | Filling Speed: | 0.1 - 100ml/min | Injection | | Sampling Repeats: | Up to 15 | Waiting Time between Samples: | 0 - 99 mins
| Injection Speed: | 0.1 - 100ml/min
| Waiting Time (before and after injection): | 0 - 99 secs |
Liquid Operation
Syringe Sizes:
| 1, 10, 25, 50 & 100μl
| Tray Capacity:
| 110 Vials, 2 or 2.5ml | Sample Volume: | Steps of 0.1μl | Air Volume: | Steps of 0.1μl | Aspirating Speed: | 1 - 100μl/sec | Needle Washing: | Up to 15 Strokes | Washing Mode: | Every Injection, Sample or Step | Air Bubble Removal: | Up to 15 Strokes | Viscosity Time: | 0 - 15 secs | Injection |
| Injection Speed: | 0.1 - 100μl/sec | Waiting Time (before and after injection): | 0 - 99 secs | Injection Depth: | Variable | Internal Standard Technique |
| IS Volume: | Steps of 0.1μl | Air Gap Volume: | Steps of 0.1μl | Mode: | 1 or 2 air gaps |
SPME Operation
Extraction:
| Liquid and Headspace
| Tray Capacity: | 40 Vials, 10 or 20ml
| Extraction Depth: | Variable | Shaking Method: | Orbital | Incubation Oven: | 6 position | Oven Temperature: | 40 - 150°C | Shaker Speed: | 320 - 720 rpm | Oven Door: | Kept closed during extraction | Fibre Cleaning Station (optional): | Variable duration |
General
Control
|
| Electrical Interfaces:
| RS232 and TTL | Physical Characteristics |
| Dimensions (W x H x D):
| 420 x 620 x 400mm | Weight: | 11.5kg | Power Supply: | 100/110/220V AC, 50/60Hz |
|
|