Instrument Database:
TraceDetect - Nano-Band Explorer Benchtop
|
|
|
|
|
|
|
Year of introduction |
|
Status |
available |
Company |
TraceDetect
|
Categories |
Electrochemistry: Voltammetry |
Now, metals testing on-site, in your hands, and under your control! The Nano-Band™ Explorer Benchtop measures trace metals in aqueous solutions, at superior detection levels. Routinely make ppm measurements instantly, ppb measurements in seconds, and ppt measurements in minutes. The system integrates our patented Nano-Band™ electrodes, Windows™-based software and a multi-parameter instrument for bench-top use: bring trace metals analysis into your lab & under your control with the Nano-Band™ Explorer! Each Explorer Benchtop system includes: - Nano-Band™ Explorer Benchtop instrument
- Explorer Software to operate your instrument
- 1 Carbon NanoBand electrode
- Auxiliary electrode
- Reference electrode
- Electrode cleaning kit
Metals testing is in your hands and under your control with user-friendly, analytical Explorer software. - Sophisticated trace metals analysis via ASV and other techniques
- Automated peak finding and identification: baseline, peak height, & peak area
- User configurable in all measurement modes
- Calibration routines, including method of standard addition
- System diagnostics
|
Specifications |
|
Power source | 108 – 132 VAC 60 Hz to wall transformer. Transformer has NEMA 5-15 plug and supplies +5V, ±12V. Combined regulation ± 5%. Typical power consumption: ~ 1 W | Controller | PC/Laptop (note: computer is not included with system, but is optional) | Host-instrument interface | Serial port, max baud rate: ~120 kbaud Supported baud rates are: 2.4 kbaud, 4.8 kbaud, 9.6 kbaud, 19.2 kbaud, 38.4 kbaud, 57.6 kbaud, and 115.2 kbaud. | Analysis capabilities | Anodic Stripping Voltammetry (ASV) Cathodic Stripping Voltammetry (CSV) Cyclic Voltammetry (CV) Square Wave Voltammetry (SqWV) Potentiometric Stripping Analysis (PSA) Amperometry Chronocoulometry Transient Response Temperature Voltage (for pH, ORP and ISE electrodes) | Measurement capabilities | Reference electrode voltage: –2.047 V to +2.048 V (12 bits), 25 µsec settling time Auxiliary electrode V-range: ± 7.5 V Current-Source ranges: – 20.47 µA to +20.48 µA and – 204.7 nA to +204.8 nA (12 bits) Measured voltages: ± 2.5 V (16 bits), 5 µsec acquisition time Measured current ranges: ± 125 µA, ± 12.5 µA, ± 1.25 µA, ± 125 nA (all 16 bit) High scan rates: 0.05V/100 µsec Minimum current resolution: 3.8 pA Temperature: 0 to 100°C, with accuracy of ±1°C at 25°C, ±2°C full temperature range Max. data rate: 25 kHz (ASV, PSA, Amperometric, CV) | Optional capabilities | 2 high-Z analog channels Rin > 1011 Ω 2 high-speed analog channels Rin > 109 Ω, 25 kHz max data rate External current measurement capability External outputs to drive oscilloscope (VRef, VMeas, and VTrig) | Dimensions, Weight, Operating ranges | 8.1” x 10.0” x 2.7” Instrument weight: 3.5 lbs. Intended temperature range of operation: 0°C to 40°C Intended humidity range of operation: 20% to 90% relative humidity | Operating system requirements | Windows 95/98/2000, Windows XP | Data file format | Export to Excel, Matlab |
|
|