Material Database:
BCR-701 - Lake sediment
Type
Certified reference material
Producer
JRC - Joint Research Centre
Status
Available
Material
Powder
Reference
BCR-701
Catalog (Web)
https://irmm.jrc.ec.europa.eu/html/reference_materials_cat
alogue/catalogue/attachements/BCR-701_report.pdf
Description
Extractable trace elements in sediment following a sequential extraction procedure
keywords:
Environmental material
,
Soil/Sediment
,
Trace elements
,
Heavy metals
,
Fractionation analysis
Package
Sediment sample in a glass bottle containing about 20 g of powder
Parameter
Analyte
Cadmium
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
0.13 +/- 0.08 mg / kg; 11.7 +/- 1.0 mg / kg
Analyte
Cadmium
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
7.34 +/- 0.35 mg / kg; 3.77 +/- 0.28 mg / kg; 0.27 +/- 0.06 mg / kg
Analyte
Chromium
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
2.26 +/- 0.16 mg / kg; 45.7 +/- 2.0 mg / kg; 143 +/- 7 mg / kg
Analyte
Chromium
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
62.5 +/- 7.4 mg / kg; 272 +/- 20 mg / kg
Analyte
Copper
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
49.3 +/- 1.7 mg / kg; 124 +/- 3 mg / kg; 55.2 +/- 4.0 mg / kg
Analyte
Copper
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
38.5 +/- 11.2 mg / kg; 275 +/- 13 mg / kg
Analyte
Lead
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
3.18 +/- 0.21 mg / kg; 126 +/- 3 mg / kg; 9.3 +/- 2.0 mg / kg
Analyte
Lead
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
11.0 +/- 5.2 mg / kg; 143 +/- 6 mg / kg
Analyte
Nickel
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
41.4 +/- 4.0 mg / kg; 103 +/- 4 mg / kg
Analyte
Nickel
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
15.4 +/- 0.9 mg / kg; 26.6 +/- 1.3 mg / kg; 15.3 +/- 0.9 mg / kg
Analyte
Zinc
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Information Value
Unit
mg / kg (Aqua regia extractable contents ( residue from sequential extraction; direct analysis))
Result
95 +/- 13 mg / kg; 454 +/- 19 mg / kg
Analyte
Zinc
Specification
Extractable trace elements in sediment following a sequential extraction procedure
Parameter
Certified value
Unit
mg / kg (Step 1; Step 2; Step 3)
Result
205 +/- 6 mg / kg; 114 +/- 5 mg / kg; 45.7 +/- 4.0 mg / kg
Events
See the complete list of deadlines!
Spectr’Atom 2025
26.05.2025
Holiday Inn Kingston Waterfront, Kingston, ON, K7L 1A2, Canada
67th ICASS: 67th International Conference on Analytical Sciences and Spectroscopy
27.05.2025
Kingston Market Square Hotel, Kingston, ON, K7L 3B1, Canada
73rd ASMS Conference on Mass Spectrometry
01.06.2025
Baltimore Convention Center, Baltimore, Maryland
... more Events
News
What's new on EVISA's web site ?
Speciation analysis in routine applications
Speciation Analysis – A Key Focus in Analytical Chemistry
Speciation analysis of lead in seafood using short-column ion chromatography coupled with ICP-MS
Selenium, Mercury, and Health Benefit Values of Ocean Fish of the Central North Pacific
... more News
Join usergroup
User:
Password:
You have forgotten your password ?
Imprint
Disclaimer
© 2003 - 2025 by European Virtual Institute for Speciation Analysis ( EVISA )