Instrument Database:
Netzsch-Gerätebau GmbH - DSC 204 F1 Phoenix Differential scanning calorimeter
|
|
|
|
|
|
|
Year of introduction |
|
Status |
historical ( out of sale ) |
Company |
Netzsch-Gerätebau GmbH
|
Categories |
Thermal Analysis: DSC |
The versatile Premium DSC 204 F1 Phoenix® fascinates with its unique concept: all essential operational components are integrated into the instrument and optional add-ons can be installed anytime on site.
The DSC measuring cell consists of a cylindrical high-conductivity silver block with an embedded heating coil for broad thermal symmetry (3D symmetry) in the sample chamber, the cooling ports for liquid nitrogen or compressed air cooling and a cooling ring for connection of the intracooler (also with simultaneous liquid nitrogen cooling). The gas-tight construction and integrated mass flow controllers for the purge and protective gases allow coupling to an FTIR or MS for gas analysis.
Exchangeable sensors are tailored to their tasks:
- With its disk-shaped silver carrier plate and supersensitive thermosensors of nickel-chromium constantan, the Tau-sensor offers a high level of calorimetric sensitivity along with extremely short signal time constants of only 0.6 seconds, which guarantees good separation of overlapping thermal effects.
- The µ-sensor stands out for its high level of calorimetric sensitivity, never before achieved with a DSC. For example, it is extremely well suited for pharmaceutical applications with small sample weights.
Important hardware extensions like the automatic sample changer (ASC) for up to 64 sample and reference crucibles and software features such as BeFlat® for an optimized baseline or the optional temperature modulation of the DSC signal (TM-DSC) make the DSC 204 F1 Phoenix® the most versatile DSC system for research & development, quality assurance, failure analysis and process optimization on the market today.
|
Specifications |
|
Temperature range: -180°C ... 700°C Wide range of heating rates: 0.001 K/min ... 200 K/min Fast cooling: max. 200 K/min Very short time constant with T-sensor Extremly high sensitivity with µ-sensor Base line optimization through BeFlat® Gas tight measuring cell, ideal for coupling to FTIR or MS Gas control for 2 sample gases and 1 protective gas through integrated mass flow controller and software Compressed air cooling: RT ... 700°C Intracooler for the extended range: -85°C ... 600°C Automatically controlled liquid nitrogen cooling: -180°C ... 700°C Automatic sample changer: DSC 204 F1 Phoenix® ASC for 64 samples and reference crucibles (option)
|
|