Instrument Database:
Agilent Technologies Inc. - G1315B (1200 Series) Diode-array Detector
|
|
|
|
|
|
|
Year of introduction |
|
Status |
available |
Company |
Agilent Technologies Inc.
|
Categories |
Chromatography: LC-Detector: Diode Array |
Complete confidence from spectral data The Agilent 1200 Series diode-array detector adds spectral acquisition to your HPLC analyses. Verify separation quality with peak purity, multiple signals and spectral libraries - interactively or automatically in the same run as your analytical quantification. Extended wavelength range from 190 to 950 nm with highest sensitivity or spectral resolution with programmable slit. And holmium oxide wavelength verification for GLP compliance. The temperature management system ensures optimum baseline stability–even under rough ambient conditions.
Features
- Access the spectral domain with superior 3D optics–simultaenous illumination using combined deuterium and tungsten lamps for highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution.
- Programmable slit to explore the spectral landscape for faster sample characterization–focus on fine bands with narrow setting, or if higher sensitivity is required open up the programmable slit for more light throughput. A broad slit ensures lowest baseline noise and highest chromatographic signal-to-noise. Store and report slit settings, from 1 - 16 nm, together with your raw data for GLP traceability.
- Convenient spectral storage and flexible viewing –easily overlaid spectra within a run or between runs.
- Verify wavelength accuracy for GLP compliance–automatic holmium oxide filter verifies that your wavelength is indeed what the setpoint says it is.
- Connect to LC/MS–high pressure micro flow cell for extremely small internal volumes are required for LC-MS applications and use a single Agilent ChemStation to acquire and view UV and MS spectral data.
- Explore capillary HPLC– flow rates as low as 5-µl/min with the new 500-nanoliter flow cell. Increase sensitivity 50 to 100-fold compared to standard-bore HPLC.
- Easy front access to lamp and flow cell for fast replacement
- Low cost of ownership - long life deuterium lamp (>2000 h), built-in diagnostics software
|
Specifications |
|
Specifications Agilent 1200 Series Diode-Array Detector | Detector type | 1024-element diode array | Light source | Deuterium and tungsten lamp | Short-term noise | ± 1.0 x 10 -5 AU at 254 nm and at 750 nm | Drift | 2 x 10 -3 AU/h at 254 nm | Linearity | >2 AU upper limit | Wavelength range | 190-950 nm | Wavelength accuracy | ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter | Slit width | Programmable: 1, 2, 4, 8, 16 nm | Diode width | < 1 nm | Wavelength bunching | Programmable, 2 - 400 nm, in steps of 1 nm | Flow cells | Standard | 13-µL volume, 10 mm cell path length, 120 bar (1760 psi) pressure maximum | Semi-micro | 5-µL volume, 6 mm cell path length, 120 bar (1760 psi) pressure maximum | Micro | 2-µL volume, 3 mm cell path length, 400 bar (5880 psi) pressure maximum | Semi-nano | 500-nanoliter volume 10-mm cell path length, 50 bar (735 psi) pressure maximum | Nano | 80 nanoliter volume., 6-mm cell path length, 50 bar (735 psi) pressure maximum | Preparative | 3-mm cell path length, 120 bar (1760 psi) pressur maximum 0.3-mm cell path lenght, 20 bar (294 psi) pressure maximum, quartz 0.06-mm cell path length, 20 bar (294 psi) pressure maximum, quartz | High pressure | 1.7-µl volume, 6-mm cell path length, 400 bar (5880 psi) pressure maximum | Time programmable | Wavelength, polarity, peak width, lamp bandwidth, autobalance, WL range, threshold, spectra storage mode | Spectral tools | Data analysis software for spectra evaluation, including spectral libraries and peak purity functions | Analog output | Recorder/integrator 100 mV or 1 V, 2 outputs | GLP
| Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded. Verification of wavelength accuracy with built-in holmium oxide filter. |
|
| |
|
|
|