Agilent Technologies Inc. - G1365C (1200 Series) Multiple Wavelength Detector SL
Year of introduction
2006
Status
available
Company
Agilent Technologies Inc.
Categories
Chromatography: LC-Detector: UV/Vis
Ultra-fast LC
Ultra fast separations can generate sharp and narrow peaks with peak widths smaller than 1 second. The Agilent 1200 Series multiple wavelength detector SL (MWD SL) offers multiple wavelength detection of 8 signals at up to 80 Hz sampling rate, keeping up with the analysis speed of ultra-fast LC. Even when operated at high data rates, the MWD SL allows precise identification and quantification at trace levels. This exceptional capability assures that your ultra-fast LC methods comply with the strictest regulatory performance requirements.
Features
Up to 100 % resolution gain in ultra-fast LC with peak widths narrower than 1 second - by 80 Hz data acquisition rate of up to 8 signals.
Minimized short-term noise (typical < ± 6µAU ASTM) - by diode-array front-end electronics.
Increased practical sensitivity - by minimized noise, RI-sensitivity and dispersion of proprietary flow cell design of the standard, semi-micro and micro flow cell with 13-µL, 5-µL and 2-µL volume.
Maximum baseline stability and practical sensitivity under fluctuating ambient temperature and humidity conditions - by NEW electronic temperature control (ETC).
"Data never lost insurance" - by built-in data recovery card (DRC). A unique data recovery functionality prevents data losses in case of communication breakdowns between instrument and PC.
Level of data traceability – Patented RFID tracking technology for flow cells and UV lamp provides a new level of data traceability by saving all relevant meta data, such as product number, serial number and cell dimensions with each individual raw data file
Maximum flexibility for optimization of resolution, linearity and sensitivity - by programmable slit width and the selection of nine different flow cells
Future-proof electronics design – Built-in web-server, USB, PCMCIA (future WLAN, Bluetooth, Firewire).
Proven robustness and performance – built upon the optical design of the best-selling DAD in the world.
Specifications
Specifications Agilent 1200 Series Multiple Wavelength Detector SL
Detector type
1024-element diode array
Light source
Deuterium and tungsten lamp
Short-term noise
< ± 0.8 x 10
-5
AU at 254 nm and at 750 nm
Drift
< 0.9 x 10
-3
AU/hr, at 254 nm
Linearity
>2 AU upper limit
Wavelength range
190-950 nm
Wavelength accuracy
± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter
Slit width
Programmable: 1, 2, 4, 8, 16 nm
Diode width
< 1 nm
Wavelength bunching
Programmable, 2 - 400 nm, in steps of 1 nm
Flow cells
Standard
13-µL volume, 10 mm-cell path length, 120 bar (1760 psi) pressure maximum
Semi-micro
5-µL volume, 6-mm cell path length, 120 bar (1760 psi) pressure maximum
Micro
2-µL, volume, 3-mm cell path length, 400 bar (5880 psi) pressure maximum
Semi-nano
500-nanoliter volume., 10-mm cell path length, 50 bar (735 psi) pressure maximum
Nano
80-nanoliter volume, 6-mm cell path length, 50 bar (735 psi) pressure maximum
High pressure
1.7-µL volume, 6-mm cell path length, 400 bar (5880 psi) pressure maximum
Preparative
3-mm cell path length, 120 bar (1760 psi) pressur maximum
0.3-mm cell path lenght, 20 bar (294 psi) pressure maximum, quartz
0.06-mm cell path length, 20 bar (294 psi) pressure maximum, quartz
Time programmable
Wavelength, polarity, peak width, lamp bandwidth, autobalance, wavelength range, threshold, spectra storage mode
Analog output
Recorder/integrator 100 mV or 1 V, 2 outputs
GLP
RFID for electronics records of flow cell and UV lamp conditions (path length, volume, product number, serial number, test passed, usage). Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded. Verification of wavelength accuracy with built-in holmium oxide filter.
Events
See the complete list of deadlines!
Winter Conference on Plasma Spectrochemistry
12.01.2026
Tucson, AZ
Gordon Research Seminar: Bioinorganic Chemistry
16.01.2026
Ventura, California, United States
Gordon Research Conference: Metals in Biology
18.01.2026
Ventura, California, United States
... more Events
News
What's new on EVISA's web site ?
The European Virtual Institute for Speciation Analysis: Promoting Speciation Analysis for More Than 22 Years – Still a Necessary Activity?
New selenium compounds found in edible mushrooms
Simultaneous Speciation Analysis of Iodine-, Gadolinium-, and Platinum-Based Pharmaceuticals by HILIC-ICP-MS and Its Application to Wastewaters
Overview of automation in speciation analysis
... more News
Join usergroup
User:
Password:
You have forgotten your password ?
Imprint
Disclaimer
© 2003 - 2025 by European Virtual Institute for Speciation Analysis ( EVISA )