Instrument Database:
Knauer GmbH - Capline System 2010 - Capillary Electrophoresis
|
|
|
|
|
|
|
Year of introduction |
|
Status |
available |
Company |
Knauer GmbH
|
Categories |
Separation: Electrophoresis, Capillary |
Capillary Electrophoresis - efficient, convenient, and versatile A3200 - Capline System 2010 The Capline System 2010 is KNAUER's fully automated high performance capillary electrophoresis system, designed for a wide range of different HPCE separation techniques. The system comes bundled with KNAUER's ChromGate® software package, which is based on latest EZChrom Elite data system. It controls the instrument functions, calculates all relevant CE specific data, such as corrected peak area and mobilities, and also supports micro preparative applications. The system contains a built-in highly sensitive UV detector to guarantee optimal performance. The wavelength is selectable at any time, even during an analysis. In addition, "stop-flow" spectra recording is supported for simplified method development. The liquid cooling of the capillary allows heat to dissipate more effectively and reproducibly than aircooled systems. Thanks to an exceedingly stable voltage feed and a highly precise, pulsation-free pressure feed for hydrodynamic injections, the Capline System 2010 offers unsurpassed reproducibility. The 10-position inlet and outlet carousels allow for flexible handling of samples, reagents and buffers. For micropreparative applications the outlet carousel can be used for fraction collection with approved fractioning algorithms.
|
Specifications |
|
Voltage Range | | -25 to +25 kV; maximum current: 200 µA, polarity manually reversible | Pressure Features | | Highly precise, pulsation-free pressure feed with syringe pump on inlet for injection (up to 30 mbar) and rinse (1000 mbar) | Mode of Operation | | Constant voltage, simultaneous freely programmable pressure | Injection Modes | | Freely programmable injection and pre/post-injection tasks; hydrodynamic injection with positive pressure (up to 30 mbar); electrokinetic injection (1 to ± 25 kV) | Temperature Control | | Peltier-driven liquid cooling; temperature range: 10 °C below ambient to 50 °C; temperature stability: ± 0.1 °C | Detector | | UV detector (190 - 380 nm); deuterium lamp; response time: 0.1 - 10 sec; "stop-flow" spectral scanning | Autosampler / Fraction Collector | | 10 position inlet carousel; 10 position outlet carousel; 1.5 ml microcentrifuge tubes; minimum sample volume: 100 µl | Safety Features | | Imin and Imax programmable; safety sensors on doors to disable high voltage | Power Requirements | | 100 - 240V, 50 - 60 Hz, 150 W | Dimensions / Weight | | 420 x 360 x 440 mm (W x H x D); 24 kg | Included Software Package | | ChromGate data system with CE specific data reporting, such as time corrected peak areas and mobility. Easy operation, multiinstrument capability, FDA 21 CFR Part 11 compliance, are some of its features. | Technical data is subject to change without notice. |
|
Related links:
|