Instrument Database:
Thermo Scientific - MAT253
|
|
|
|
|
|
|
Year of introduction |
|
Status |
available |
Company |
Thermo Scientific
|
Categories |
Mass spectrometer: IRMS |
The MAT 253 stable isotope ratio mass spectrometer system delivers the highest sensitivity and the highest precision for the determination of isotope ratios. The MAT 253 provides a flexible and open platform for the connection of inlet systems and preparation devices. The ISODAT NT isotope data systems ensures easy set up, tuning and fully automatic operation. Product Detail | | | | The MAT 253 stable isotope ratio mass spectrometer system delivers the highest precision for the determination of H/D, 13C/12C, 15N/14N, 18O/16O, 34S/32S (from SO2 and SF6), 28Si/29Si as well as Ar, Kr and Xe isotope ratios. It is unique in its capability to achieve precision measurements from the smallest amounts of sample. The MAT 253 provides a flexible and open platform for the connection of inlet systems and preparation devices. ThermoFisher Scientific supplied inlet systems are automatically recognized by a "plug and measure" concept. In addition, the system is open for easy connection and control of custom inlet/preparation systems. Full integration of ISODAT 2.0, the dedicated gas isotope data system, enables the MAT 253 to be easily set up, tuned and run fully automatically. The powerful ISODAT Script Language ISL provides access to all processes and allows modification of supplied scripts as well as development of entirely new measurement and evaluation protocols. The NEW Standard for IRMS - Amplifiers register up to 50 V
- Computer switchable amplifier gain
- Hydrogen continuous flow capability
- Highest sensitivity and linearity
- "Fast bellows" system
- Computer-controlled ion source potentials and parameters
- Up to eight simultaneous acquisition channels
- "Plug and measure" peripheral recognition
- Total ISODAT 2.0 integration
- Small footprint
All the features of the established standard, the MAT 252 - 10 kV acceleration voltage
- Ion source with variable conductivity
- All-metal sealed ion source and analyzer
- Monolithic all-metal valves with gold gaskets
- 100 % analyzer transmission
- 460 mm mass dispersion
- Mass range m/z 1 - 150 at full acceleration voltage
- Mass resolution 200 (C,N,O,S)
- The only system for e.g. SF6, SiF4, Xe ...
- Proven robustness
|
|
Specifications |
|
Mass range : | 1 - 150 dalton at 10 kV | Resolution : | CNOS: m/delta m = 200 (10 % valley), H/D : m/delta m = 25 (10 % valley) | Peak Top Flatness : | Better than 2 x 10e-4 | Sensitivity (absolute) : | 600 molecules CO2 per mass 44 ion at the collector (600 colecules/ion) | Abundance Sensitivity : | The contribution of the mass 44 intensity to the intensity of mass 45 is less than 2 x 10e-6 | Sample Consumption : | 0.031 nmol/s for 1.5 V signal (5 nA) at mass 44 in the Dual Inlet mode 0.047 nmol/s for 1.5 V signal (5 nA) at mass 44 in the Continuous Flow mode | Ion Source Linearity : | 0.02 ‰/nA ion current (mass 44) at a sensitivity corresponding to 900 molecules/ion | H3+ Factor : | Smaller than 10 ppm/nA |
|