Instrument Database:
Jobin Yvon Horiba - JY 2000-2 ( HORIBA Jobin Yvon )
|
|
|
|
|
|
|
Year of introduction |
|
Status |
historical ( out of sale ) |
Company |
Jobin Yvon Horiba
|
Categories |
Spectrometer ( Atom. ): AES: ICP-AES |
Low-Cost ICP OES/AES Performance in A Platform for the Future™ JY knows that one design does not fit all and your applications are unique to your laboratory, even if they are routine. The JY 2000 2, the second in the series of instruments defining A Platform for the Future™, offers exceptional value with pricing designed to meet even the most challenging budget. - Optical design maintains the elegance and simplicity necessary to provide maximum light throughput and still provide excellent performance in resolution.
- New sample introduction area with a focus on productivity.
- No other ICP spectrometer today offers better performance than the JY 2000 2 except the ULTIMA 2! Typical detection limit for Pb is 5 ppb on a radial view plasma. Radial view minimizes interferences.
- Continuous wavelength coverage from 160 to 800nm as a standard with optional extension to 120nm for VUV analysis of the halogen elements or the use of alternative wavelengths.
|
Specifications |
|
Dimensions (w x d x h in cm)
| | Weight (kg)
| | Power
| Single phase, 3 kW, 30 A, 220/240 V, 50/60 Hz
| Spectrometer
| Czerny-Turner monochromator, nitrogen purged, thermostated
| Grating | ion-etched holographic master, 80 x 100 mm, 2400 lines/mm used in first/second order (4320 lines/mm optional)
| Optics
| | Wavelength range | 160 - 800 nm (120-800 nm optional)
| Wavelength drive | direct drive grating mount; Full range in 10 s; reproducibility +- 0.4 pm
| Resolution | 8 pm for < 320nm
| Detector | High Dynamic Detector (HDD)
| Detection mode
| | Read out | |
| | ICP generator
| solid state generator, frequency stabilized; reflected power control, air cooled | Frequency (MHz) | 40.68
| Power (Watt)
| 2600 | Load coil
| water cooled
| Torch
| fully demountable, radially viewed
| Argon flow (L/min)
| 12 (7 low-flow option)
|
| | Sample introduction | thermoregulated sample compartment; cassette design for easy exchange of the torch, sheat gas for reduced memory effects
| Operating system and software
| JY Analyst; Windows 95/98/2000/NT compatible software
| Computer
| | Short term precision (RSD for 10 replicates)
| | Long term precision (RSD for 4 hours)
| | Sensitivity
| | Detection limits (3s, µg/L) | | Accessories
| hydride generator; HF-resistant nebulizer and injector, ultrasonic nebulizer
| Special features
| |
|