ESA Inc. - Model 584 Solvent Delivery Module
|
|
|
|
|
|
|
Year of introduction |
|
Status |
historical ( out of sale ) |
Company |
ESA Inc.
|
Categories |
Chromatography: LC-Pump: Gradient/Binary |
The ESA Model 584 solvent delivery module offers significantly improved solvent delivery performance through improvements in solvent-delivery control firmware. With an automatic pulsation-correction mechanism and high-speed micro plunger drive, it achieves pulse-free solvent delivery even at micro-flow-rate ranges below 50µL/min. Enhanced Solvent Delivery
Flow-rate accuracy and precision in the micro-flow rate region have been improved with the addition of an improved check valve design and modifications to the solvent delivery control method.
Improved Durability
New and improved sapphire plungers with optimized crystal structure and a precision plunger-holding mechanism provide long-lasting performance and enable stable solvent delivery.
Features
- Dual Parallel Plungers - provide low pulsation and greater seal life.
- Micro Volume Piston Displacement - 10 µL per plunger stroke, gives improved LOD with electrochemical detection
- Flow Rate Range of 0.0001 - 10 mL/minute - usable for analytical, microbore and LC-MS applications
- Automatic Seal Wash - prolongs piston seal life for greater reliability.
- Enhancement Package - for reduced noise with electrochemical detection.
- Electronic Diagnostics - for easier maintenance.
- Improved Fluidics - made more reliable and easier to service
- High Gradient Accuracy and Precision - for greater reproducibility
|
Specifications |
|
Pump Design: | Micro-volume dual plunger (approximately 10 microliters/stroke) | Modes of Solvent Delivery:
| Constant flow or constant pressure solvent delivery | Flow Rate Range: | 0.0001 - 5 mL/minute (10 - 340 bar); 5.0001 - 10.0000 mL/minute (10 - 200 bar) | Flow Rate Accuracy: | No more than 1% or 0.5µL/min., whichever is greater (0.01 to 2 mL/min), exclusive of low pressure gradient module | Flow Rate Precision: | 0.3% max. (RSD: 0.1% max.) (0.1 - 5 mL/minute, 10 - 340 bar with water and room temperature at 20°C) | Damper (External): | Internal capacity of approximately 0.8 mL | Materials in Contact: | 316 stainless steel, ruby, sapphire, Teflon®, PEEK, HastelloyC® | Piston / Seal Cleaning | Automatic with supplied seal wash kit | Mobile Phase Filter: | Inert 10 µm mesh | Time Program: | Commands for flow rate, pressure, [EVENT] functions, [LOOP] (for program repetition), with a total of 10 files and 320 steps | Pressure Indication Accuracy: | ±2% or 5 bar, whichever is greater | Safety controls: | Liquid-leakage sensor, high-pressure/low-pressure limits | Size: | 10" (W) x 5" (H) x 16.5" (D) (260 mm x 140 mm x 420 mm), however protruding components are not included | Weight: | 22 lbs (~10 kg) | Operating Temperature Range: | 41 - 95°F (5 - 35°C) | Power Requirements: | 90 - 240 VAC, 150 VA, 50/60 Hz | Safety Certifications: | US: ANSI/UL 61010-1 Canada: CAN/CSA 6010-1-1: 2004 EU: IEC 61010-1-2001 |
|
|