OSHA Method ID-145: PARTICULATE MERCURY IN WORKPLACE ATMOSPHERES
Description
This method describes the collection of airborne particulate mercury on 0.8-µm mixed-cellulose ester membrane (MCE) filters and the subsequent analysis using a cold vapor-atomic absorption spectrophotometer (CV-AAS). Wipe and bulk samples can also be collected and analyzed for mercury content using this method.
|