Glossary on
|
Contact EVISA
|
Sitemap
|
Home
Training
QA/QC
Analytical Services
Database
Consultancy
Research
Newsletter
Vacancies
EVISA - Who we are
About Speciation
Discussion Forum
Services
Links
Glossary
Search
The establishment of EVISA is funded by the EU through the Fifth Framework Programme (G7RT- CT- 2002- 05112).
Supporters of EVISA includes:
Instrument Database:
Shimadzu Europe - SPD 10AV UV-Vis Detector
Year of introduction
Status
historical ( out of sale )
Company
Shimadzu Europe
Categories
Chromatography: LC/HPLC
Specifications
Light source:
Deuterium lamp, tungsten halogen lamp
Wavelength rang:
-190-900nm
-190-370nm (deuterium lamp)
-371-900nm (tungsten halogen lamp)
Spectral bandwidth:
8nm
Wavelength accuracy:
± 1nm
Wavelength reproducibility:
± 0.1nm
Drift:
3x10
-4
AV Max. (250nm, 600nm, room temperature fluctuation less than 2°C, air in the cell)
Baseline noise:
10x10
-5
AU Max. (250nm, 600nm, air in the cell. equivalent to 1 sec time constant)
Cell length, cell volume:
10mm, 8ul
Cell pressure tole-rance:
30kgf/cm
2
Cell materials in contact with liquid:
SUS316, PTFE, quarts
Cell inlet, outlet tube dameter:
USS316 tube 1/16"OD x 0.3mmID
Dual wavelength
-
Measuring wavelength:
Arbitrary two wavelengths in 190-370 nm, 371-700nm, or 701-900nm
- Sampling period:
1.2 sec for one wavelength
Response:
selectable in 9 steps corresponding to time constant 0.05, 0.1, 0.5, 1.0, 1.5, 3.0, 6.0, 8.0, 10.0 seconds
Range:
Can be set to from 0.0001 to 2.56AU/FS every 0.0001 AU/FS step.
Events
See the complete list of deadlines!
EMEC 24: European Meeting on Environmental Chemistry
26.11.2024
Alicante, Spain
23rd ICFIA: International Conference on Flow Injection Analysis and FRelated Techniques
03.12.2024
The Empress Hotel, Mueang, Chiang Mai, Thailand
PittCon 2025
01.03.2025
Boston, Massachusetts
... more Events
News
What's new on EVISA's web site ?
Liquid chromatography hyphenated with inductively coupled plasma optical emission spectrometry (LC-ICP-OES) for speciation analysis
Ion chromatography hyphenated with inductively coupled plasma optical emission spectrometry (IC-ICP-OES) for the determination of inositol phosphates in food and feed
Mercury-Contaminated Tuna: An Unprecedented Health Scandal
Quantification of Technetium-99 in Wastewater Using Online Preconcentration and Anion-Exchange Chromatography Coupled with Inductively Coupled Plasma-Mass Spectrometry
... more News
Join usergroup
User:
Password:
You have forgotten your password ?
Imprint
Disclaimer
© 2003 - 2024 by European Virtual Institute for Speciation Analysis ( EVISA )