Instrument Database:
Thermo Scientific - iCAP™ 7200 - ICP-OES Analyzer
|
|
|
|
|
|
|
Year of introduction |
2014 |
Status |
available |
Company |
Thermo Scientific
|
Categories |
Spectrometer ( Atom. ): AES: ICP-AES |
Provide entry level, cost-effective analysis for low sample thru-put requirements with the Thermo Scientific™ iCAP™ 7200 ICP-OES.
Inductively Coupled Plasma (ICP) Optical Emission Spectrometry (OES) is a well established and powerful technique for the analysis and quantification of trace elements in both liquid and solid samples.
Sample Introduction System:
The instrument is supplied with analysis-ready sample introduction parameters, so users no longer required to optimize pump speed, plasma RF power and gas flow rates.
- A 3-channel, 12-roller peristaltic pump, with a unique drain sensor, provides smooth, low noise signals and safe operation
- Bayonet torch fitting for easy assembly/disassembly
- Clip-together sample introduction system for easy re-configuration and maintenance
- Enhanced Matrix Tolerance (EMT) torch design improves the handling of high matrix samples
- Optical drain sensor detects liquid flow from the spray chamber and automatically switches the plasma off in case of incorrect drainage, saving samples, gas and power
- A range of CETAC autosamplers are available to enable optimization of the iCAP 7200 ICP-OES for automated, unattended analysis
Plasma and RF Generator:
- Duo (axial and radial) plasma viewing
Optical System:
- Low gas purge flow rates for the optical system help reduce running costs
- High-transmission optical design for exceptional sensitivity
- High-resolution echelle spectrometer increases accuracy by reducing spectral overlap
- Thermostatically controlled polychromator with thermal-break design enhances long-term stability, allowing extended analytical runs without recalibration
Detector:
- Charge Injection Device (CID) detector: CID-86
- Free, continuous choice of wavelengths in the range 175 to 847nm
- Resistance to adjacent-pixel blooming, reducing false positive results in complex sample matrices
- Nondestructive readout and random access integration increase signal-to-background ratio and detection limits
Software:
- Intuitive Qtegra™ Intelligent Scientific Data Solution™ platform software, with pre-loaded method template as standard, enables "Out of box" operation
|
Specifications |
|
Type | iCAP™ 7200 ICP-OES Duo | Detector Type | High performance solid-state CID86 chip | Wavelength Range | 175 to 847nm | Auxiliary Gas | Fixed, 4 flows 0, 0.5, 1.0 and 1.5L/min | Data Acquisition Modes | Standard precision mode | Depth (Metric) | 750mm | Features | Get ready: automatic performance checks features | Height (Metric) | 590mm | Nebulizer Gas | Pressure control, from 0 to 0.4MPa | Peristaltic Pump | 3-channel, 12 roller peristaltic pump, Speed: 0 or 45rpm | Plasma Gas | Fixed, 12L/min | Plasma Viewing | Duo | Pre-loaded Method Templates | Environmental, Food, Toy safety, WEEE/RoHS | RF Source | 27.12MHz solid state, 750 to 1500w output power (Optimized at 1150w) | Spectral Bandpass | 7pm at 200nm | Spectrometer | Simultaneous echelle type, 52.91 grooves/mm ruled grating, 383mm effective focal length, 9.5° UV fused silica cross dispersion prism | Standard Sampling Kit | Concentric glass nebulizer, Glass cyclonic spray chamber, Semi-demountable EMT torch, 2mm bore quartz center tube | Width (Metric) | 840mm |
|
|