Instrument Database:
Thermo Scientific - Dionex™ ICS-5000+ Hybrid HPIC™ System
|
|
|
|
|
|
|
Year of introduction |
2012 |
Status |
historical ( out of sale ) |
Company |
Thermo Scientific
|
Categories |
Chromatography: LC/IC |
Get best-in-class resolution, sensitivity, and throughput for even the most complex ICxIC (2D-IC) methods and trace level analyses. The versatile Thermo Scientific™ Dionex™ ICS-5000+ Hybrid HPIC™ System provides faster separations without compromising resolution, thanks to its dual high-pressure channels: one optimized for capillary flow rates, the other for standard (4mm) or microbore (2mm). You'll save time and improve reproducibility with precise, automatic eluent generation and sample preparation. Choose from a wide variety of chemistries, detectors, and automation options to fit your needs.
Built on our top-of-the-line IC platform, this system provides the high performance, convenience, and flexibility of the Thermo Scientific™ Dionex™ ICS-5000+ HPIC System with the power of parallel analytical and capillary channels.
Run two analyses concurrently on a single sample, analyze two samples, or perform advanced IC × IC (2D-IC) techniques. The Dionex ICS-5000+ Hybrid HIPC System is ideally suited for trace level determinations with high matrix concentrations, using a standard or microbore column in the first dimension to separate analytes from matrix, followed by a capillary separation in the second dimension. This method provides high sensitivity, enabling conductivity detection limits to rival those of mass spectrometry.
High Pressure, High Performance
- Fast, sensitive separations without sacrificing resolution—up to two times faster still with Fast IC columns
- Outstanding resolution using columns with small-diameter particles, thanks to high-pressure capability
- Continuous operation at up to 5000 psi when configured as a Reagent-Free™ IC (RFIC™) system
- Optimized peak resolution with a choice of isocratic and electrolytic gradient separations on either channel, or optional quaternary low pressure gradients on the standard/microbore channel
- Flexible support for standard bore (3–7mm I.D.)and microbore (1–3mm I.D.) columns on one channel and capillary columns (0.2–0.6mm I.D.) on the other
- Wide variety of chemistries available in Thermo Scientific™ standard bore, microbore, capillary, and Fast IC columns
- Flexible, easy to configure, modular design
The Capillary Advantage
The capillary channel in this hybrid system presents added advantages:
- Always ready with 24/7 uptime and minimal calibration and equilibration time
- Up to 18 months of continuous operation on one Eluent Generation cartridge
- Small dead volumes for minimized peak dispersion and increased signal-to-noise ratio
- Reduced eluent disposal costs—only 15mL/day for continuous operation at 10µL/min
- Enhanced ease-of-use with Thermo Scientific™ Dionex™ IC Cube™ capillary consumable cartridges
Choose from a broad variety of Dionex ICS-5000+ modules and related products. See the Dionex ICS-5000+ HPIC System Product Features for a full list.
Sample Preparation and Automation Solutions
Dionex autosamplers integrate seamlessly with all Dionex ICS-5000+ HPIC systems, providing effortless automation and advanced sample preparation capabilities.
|
Specifications |
|
Type | Single or Dual channel RFIC hybrid package;MB, Cap
| Detector Type
| CD, ED, UV-Vis
| Flow Rate Range
| Analytical 0.00 to 10.00; Capillary 0.001 to 0.100mL/min
| Max. Pressure
| Analytical Pump 5000, ER 3000; Capillary 6000psi
| Gradient Profiles
| Any combination of an unlimited number of linear, convex, and concave positive and negative
|
|